Write 2 experiments that proves that oxygen is used up in respiration.Explain in detail how does this done and what are the things used?

1 Answer

One method is using a respirometer with woodlice or another small organism inside it, another method is using a spirometer

Explanation:

Respirometer apparatus can be set up as shown:

![http://ib.bioninja.com.au/standard-level/topic-2-molecular-biology/28-cell-respiration/http://respirometry.html](https://useruploads.socratic.org/RrLBUvGYRra5TBH3ynrD_manometer_med.jpeg) This involves two containers, connected by a capillary tube containing a coloured fluid (a manometer).

A live organism (eg a woodlouse) is placed in one container, along with a CO2 absorbent (eg potassium hydroxide solution) to remove any CO2 produced by the respiring organism.

A glass bead of equal mass and volume is placed in the other container to ensure both containers are identical in every way other than the presence of the organism, so that the only variable is the amount of O2 consumed.

As the organism present respires, it will consume O2, causing the pressure of the gas in the container on the left-hand side to decrease, drawing the coloured fluid in the manometer up into the left side. The distance moved by the coloured fluid can then be used to calculate the volume of O2 that was lost from the left container, if the width of the manometer tube is known. This is done using the equation for the volume of a cylinder V=πr2h. The average rate of O2 consumption can then be measured by dividing the volume of O2 consumed by the time.

Similarly, spirometer apparatus can be set up as shown:

![http://www.nuffieldfoundation.org/practical-biology/using-spirometer-investigate-human-lung-function](useruploads.socratic.orguseruploads.socratic.org)

A spirometer works in much the same way as a respirometer. A patient inhales in and out of the mouthpiece. Any CO2 they breathe out is absorbed by a CO2 absorbant, so the only change in the inside of the spirometer is a gradual decrease in O2 present as more and more of it is absorbed by the patient.

An image trace as shown is produced:

![http://www.nuffieldfoundation.org/practical-biology/using-spirometer-investigate-human-lung-function](useruploads.socratic.orguseruploads.socratic.org)

As the patient exhales, the volume of the spirometer increases, and vice versa as the patient inhales. This causes the peaks and troughs shown on the graph. The average volume of the spirometer gradually decreases as O2 is absorbed by the patient.

The rate at which the graph decreases (ie the gradient of the trend line) can be found - this gives a rate for average O2 consumption, in dm3s1.